Facility Maintenance
Units: | - |
Mode: | Input/Output Only |
Max Bands: | 1 |
Default Value: | 0 |
Validation Rule: | Any Value |
Key Property: | No |
Description: | Capacity lost to maintenance |
Detail: |
- Input
-
Facility Maintenance is the production capacity on maintenance outage. This can be defined using a Variable or passed as an input from an Interleaved simulation to coordinate maintenance outages between models.
- Output
-
The definition of the Maintenance as an output varies by simulation phase:
- LT Plan
-
Maintenance reports the derating applied to capacity to account for Maintenance Rate:
Maintenance = ∑ ( b ) ( Maintenance Rateb × (Max Operating Level - Outage Ratingb)
where:
b indexes the bands of Maintenance Rate - PASA
-
Maintenance is the sum of the user-defined maintenance and the 'idealized' maintenance profile:
Maintenance = Discrete Maintenance + Distributed Maintenance
- MT Schedule and ST Schedule
-
Maintenance reports the capacity on maintenance from the realized maintenance events (combination of user-defined and those generated by PASA). Thus for any given event:
Maintenance =∑ ( b ) (Max Operating Level - Outage Ratingb) × Units Outb
Note that if MT Schedule Chronology = "Partial" then multiple discrete events may combine together in any given period as a function of the slicing of the duration curves and thus this profile may then resemble a sculpted derating rather than discrete events.
See also: