Facility Maintenance

Units: -
Mode: Input/Output Only
Max Bands: 1
Default Value: 0
Validation Rule: Any Value
Key Property: No
Description: Capacity lost to maintenance
Detail:
Input

Facility Maintenance is the production capacity on maintenance outage. This can be defined using a Variable or passed as an input from an Interleaved simulation to coordinate maintenance outages between models.

Output

The definition of the Maintenance as an output varies by simulation phase:

LT Plan

Maintenance reports the derating applied to capacity to account for Maintenance Rate:

Maintenance = ∑ ( b ) ( Maintenance Rateb × (Max Operating Level - Outage Ratingb)

where:
b indexes the bands of Maintenance Rate

PASA

Maintenance is the sum of the user-defined maintenance and the 'idealized' maintenance profile:

Maintenance = Discrete Maintenance + Distributed Maintenance

MT Schedule and ST Schedule

Maintenance reports the capacity on maintenance from the realized maintenance events (combination of user-defined and those generated by PASA). Thus for any given event:

Maintenance =∑ ( b ) (Max Operating Level - Outage Ratingb) × Units Outb

Note that if MT Schedule Chronology = "Partial" then multiple discrete events may combine together in any given period as a function of the slicing of the duration curves and thus this profile may then resemble a sculpted derating rather than discrete events.

See also: