Facility Max Units Retired in Year

Units: -
Mode: Input Only
Multi-band: False
Default Value: 1E+30
Validation Rule: ≥0
Key Property: No
Description: Maximum number of units automatically retired in any single year of the planning horizon
Detail:

Facility Max Units Retired in Year set the maximum number of units automatically retired in any single year of the planning horizon in LT Plan. The value should be less than or equal to the total units allowed to retire which is set by Max Units Retired.

Table 1: Max Units Retired Example
Property Value Units Date From Date To
Units 1 -

Max Capacity 500 -

FO&M Charge 25,000,000 $

Max Units Retired 1 -

Min Units Retired 1 -

Retirement Cost 10000 $000

Max Units Retired in Year 0 - 1/01/2010 31/12/2015


In this example the sole unit must retire at some time in the planning horizon, but cannot retire between the years 2010-15.