Gas Storage Withdrawal Rate Scalar

Units: %
Mode: Input Only
Multi-band: True
Default Value: 0
Validation Rule: Any Value
Key Property: No
Description: Scalar to set the maximum amount of gas that can be withdrawn from the storage
Detail:

Gas Storage Withdrawal Rate Scalar scales the Withdrawal Ratchet to set an upper bound on the maximum amount of gas that can be withdrawn from the storage within a particular time period and band. This value corresponds with the Withdrawal Volume (or Withdrawal Volume Factor if using percentage based ratchets) for the given band.

When Use Additive Ratchet is Yes, the input is incremental, starting from the last band to the first. For example:

Property Value Units Band
Withdrawal Volume 400 TJ 1
Withdrawal Rate Scalar 50 % 1
Withdrawal Volume 300 TJ 2
Withdrawal Rate Scalar 30 % 2
Withdrawal Volume 300 TJ 3
Withdrawal Rate Scalar 20 % 3
Withdrawal Ratchet 100 TJ 1

In this case, band 1, which has a volume of 400 TJ, can be withdrawn from at a rate of (0.5 + 0.3 + 0.2) * 100 TJ per time period. Band 2, which has a volume of 300 TJ, can be withdrawn from at a rate of (0.3 + 0.2) * 100 TJ per time period, after band 1 has been depleted. Lastly, band 3, which has a volume of 300 TJ, can be withdrawn from at a rate of 0.2 * 100 TJ per time period, after bands 1 and 2 have been depleted.