Generator Max Ramp Down
Units: | MW/min |
Mode: | Input/Output |
Multi-band: | True |
Default Value: | 1E+30 |
Validation Rule: | ≥0 |
Key Property: | No |
Description: | Maximum ramp down rate that applies at the given load point |
Detail: |
Generator Max Ramp Down sets a limit on the rate at which the generator can decrease production and is expressed in megawatts per minute. This property is multi-band which allows for different ramp limits depending on the generation level. If a single band is defined, then this limit applies for Generation ranges between Min Stable Level and Max Capacity, unless Run Down Rate or Shutdown Profile are defined in which case this ramping limit applies before shutdown begins.
To define different ramp limits depending on generation level, pair bands of the Max Ramp Down with Ramp Down Point.
For multi-unit generating stations the available ramp down is defined as:
-
Max Ramp Down (station) = Units
Generating × Max Ramp Down
When modelling Reserve the amount of available ramping down capability may be reduced by the provision of lower ancillary services. See the Response Ratio property for more details.
By default the ramping limit is a hard constraint meaning that no violation is allowed. To create soft constraints with a penalty price use the Max Ramp Down Penalty property.
Property | Value | Units |
---|---|---|
Units | 1 | - |
Max Capacity | 100 | MW |
Min Stable Level | 40 | MW |
Max Ramp Up | 0.5 | MW/min. |
Max Ramp Up Penalty | 100 | $/MW |
Max Ramp Down | 0.5 | MW/min. |
Max Ramp Down Penalty | 100 | $/MW |
To model the running down period where Generation
is between Min Stable Level
and zero use either the Shutdown
Profile or Run Down Rate
properties.
Related reporting properties:
- Generator Ramp
- Generator Ramp Down Price
- Generator Ramp Down Violation Hours
- Generator Ramp Down Violation
- Generator Ramp Down Violation Cost
See also: