Generator Min Stable Level
Units: | MW |
Mode: | Input Only |
Multi-band: | False |
Default Value: | 0 |
Validation Rule: | ≥0 |
Key Property: | No |
Description: | Minimum stable generation level |
Detail: |
Generator Min Stable Level is the minimum stable generation level of each generating unit. This minimum level is enforced when the unit is turned on i.e. after the unit has run up and before it runs down. Specifically the following constraint is enforced:
Generation ≥ Units Generating × Min Stable Level
Units Generating integer
Note that the integrality constraint is relaxed if Unit Commitment Optimality is set to "Linear Relaxation" since Units Generating in that case is a continuous variable.
Property | Value | Units |
---|---|---|
Units | 4 | - |
Max Capacity | 250 | MW |
Min Stable Level | 40 | MW |
For the example in Table 1 each unit will operate between the range
40-250 when 'on'. When all units are 'on' the minimum is 4 x 40 = 160
and the maximum 4 x 250 = 1000 for the facility as a whole.