Generator Run Up Rate

Units: MW/min
Mode: Input Only
Multi-band: True
Default Value: 1E+30
Validation Rule: ≥0
Key Property: No
Description: Ramp rate that applies while running the unit up from zero to [Min Stable Level].
Detail:

By default generating units are assumed to run up instantaneously. To override this behaviour Generator Run Up Rate defines a ramping limit that applies while the generating unit is running up from zero to Min Stable Level. This property is a simplified version of Start Profile and is used when the run up rate is constant for any given cooling state.

Note that this run up rate can be different to the Max Ramp Up which applies in the normal operating range, and Max Ramp Up does not need to be defined to use Run Up Rate.

Example:

Property Value Unit
Units 1 -
Max Capacity 100 MW
Min Stable Level 40 MW
Run Up Rate 0.5 MW/min.

Run Up Rate is a multi-band property where each band corresponds to a cooling state. Cooling states are defined using multi-band Start Cost and Start Cost Time. In the following example the unit is 'hot' when it has been shut down for less than six hours and can run up at a rate of 0.75 MW/min. If the unit has been shut down for longer than six hours, it has been "cooled" down, and the run-up rate slows down to 0.5 MW/min.

Example:

Property Value Unit Band
Units 1 - 1
Max Capacity 100 MW 1
Min Stable Level 40 MW 1
Start Cost 5000 $ 1
Start Cost 9000 $ 2
Start Cost Time 6 hrs 1
Start Cost Time 2 hrs 2
Run Up Rate 0.75 MW/min. 1
Run Up Rate 0.5 MW/min. 2