Generator Ramp Flexibility Up

Units: MW
Mode: Output Only
Multi-band: False
Default Value:
Validation Rule:
Key Property: No
Description: Amount of unused ramp up capability
Detail:

Generator Ramp Flexibility Up is the amount of unused ramp up capability given the current commitment state:

Ramp Flexibility Upt = MIN ( Rating × Units Generatingt - Generationt-1 - Ramp Upt , Max Ramp Up × Units Generatingt × time - Ramp Upt )

Other technical constraints are also included, such as the start and shutdown profiles. When the generator is starting or shutting down, it cannot provide any additional ramp up/down capacity.

See also: