Generator Ramp Flexibility Down
Units: | MW |
Mode: | Output Only |
Multi-band: | False |
Default Value: | |
Validation Rule: | |
Key Property: | No |
Description: | Amount of unused ramp down capability |
Detail: |
Generator Ramp Flexibility Down is the amount of unused ramp down capability given the current commitment state:
Ramp Flexibility Downt = MIN ( Generationt-1 - Min Stable Level × Units Generatingt-1 - Ramp Downt , Max Ramp Down × Units Generatingt-1 × time - Ramp Downt )Other technical constraints are also included, such as the start and shutdown profiles. When the generator is starting or shutting down, it cannot provide any additional ramp up/down capacity.