Line Formulate Upfront
Units: | Yes/No |
Mode: | Input Only |
Multi-band: | False |
Default Value: | False (0) |
Validation Rule: | False (0) or True (-1) |
Key Property: | No |
Description: | If constraints should all be formulated upfront rather than checked iteratively. |
Detail: |
Line Formulate Upfront controls when the thermal limits for the Line are added to the mathematical programming problem. The setting can take these values:
- False (value = 0)
- Constraints are added only when the Flow on the Line exceeds the Max Flow or Min Flow.
- True (value = -1)
- Constraints are added during simulation initialization.
In general it is more efficient to add constraints only as needed but in some cases performance maybe improved by adding the constraints upfront, avoiding additional iterations.
See also:
- Transmission Formulate Upfront
- Transformer Formulate Upfront
- Interface Formulate Upfront