Production Heat Rate Detail

Units: -
Default Value: 0
Validation Rule: In (0,1,2)
Description: Level of detail for Generator heat rate modelling
Detail:

Production Heat Rate Detail can take the following values:

Detailed (value = 0)
Generator heat rates are modelled according to their definitions, with level of detail controlled by the Generator Max Heat Rate Tranches setting.
Simple (value = 1)
Generator heat rates are simplified to a no-load cost plus single band of marginal heat rate at Generator Max Capacity.
Simplest (value = 2)
Generator heat rates are approximation by the average heat rate at Generator Max Capacity.