Region Constraints Generation Capacity Coefficient

Units: MW
Mode: Input Only
Multi-band: False
Default Value: 0
Validation Rule: Any Value
Key Property: No
Description: Coefficient of total generation capacity
Detail:

Region Constraints Generation Capacity Coefficient is the left-hand side coefficient of the total Region Generators Firm Capacity in the constraint.

With the coefficient represented by a(i,j) the following term is added to the formulation:

... + a(i,j) × ∑ ( Region Generators ) ( Firm Capacity ) ... {≤, ≥, =} bj


where:
k
is the current period e.g. year of the simulation.

See also: