Reserve Dynamic Risk

Units: Yes/No
Mode: Input Only
Multi-band: False
Default Value: True (-1)
Validation Rule: False (0) or True (-1)
Key Property: No
Description: If elements in the Generator Contingencies and Line Contingencies collections are considered for dynamic risk calculations
Detail:

Reserve Dynamic Risk toggles on/off consideration of dynamic risk in the ancillary services co-optimization. With this switch toggled on, the Risk for each class of reserve considers the maximum of Generation from the Generators listed in the Generator Contingencies collection, and the maximum of Flow on the Lines listed in the Line Contingencies collection. Note that the contribution of Flow to the risk is determined by the properties Flow Forward Coefficient and Flow Back Coefficient.

See also: