Reliable Capacity Column
Column Type = Text

The optional Reliable Capacity column, when populated, takes the place of the following standard calculation:

[Capacity]*[Capacity Monthly Shape]*[Peak Credit]

This column offers the convenience of not having to worry about capacity changing over time, especially when trying to match up the Peak Credit with capacity to get the desired peak capacity counted towards the reserve margin.  

Essentially, everywhere the formula above is used, Aurora will check to see if the Reliable Capacity is populated for that time period, and if so, it will use the Reliable Capacity value instead. This includes calculating the reserve margin, the capacity revenue, and the maintenance scheduling logic.  

Here are a few things to note:

[Capacity]*[Capacity Monthly Shape]*[Hourly Shaping Factor]*[1 – Forced Outage/100]*[1 – Maintenance Outage/100]*[Peak Credit]

Since the Reliable Capacity input is meant to replace [Capacity]*[Capacity Monthly Shape]*[Peak Credit], when it is specified for a DSM resource, the contribution to the reserve margin becomes:

[Reliable Capacity]* [Hourly Shaping Factor]*[1 – Forced Outage/100]*[1 – Maintenance Outage/100]

 

 

 NOTE: This column is not used if the record references a Base Resource ID.

 

 NOTE: Specify inputs for any time period (annually, monthly, weekly, hourly, or sub-hourly). For information on specifying a variable's time series, see Entering a Time Series.

 

 Input Tables

 Fuel Table

 Reliable Capacity Column


For further assistance, please contact Aurora Support.

Copyright© 1997-2024 Energy Exemplar LLC. All rights reserved.