Start Up Hours Hot Column
Column Type = Text

This optional column defines the hot start period for a unit and should be entered as an integer value larger than 0. When a unit has been down this many hours or less and starts up again, the start cost amount is defined by the Start Up Costs Factor Hot and Start Fuel Factor Hot columns.

Note that if the unit has been down a number of hours that is between the Start Up Hours Hot and the Start Up Hours Warm, or between Start Up Hours Warm and Start Up Hours Cold, Aurora will do a linear interpolation between the two corresponding costs to figure out the cost to start at that hour.

For example, if the total warm start up cost is $10,000, the total cold start up cost is $20,000, the Start Up Hours Warm is 20, the Start Up Hours Cold is 40, and the unit start up after 30 hours, the cost will be $15,000. 

 

 NOTE: If the FUEL reference is specified for this variable the value in the Fuel Table will be applied.

 

 Input Tables

 New Resources Table

 Start Up Hours Hot Column


For further assistance, please contact Aurora Support.