Spinning Reserve MW Reqt Column
Column Type = Text

Optional column for the spinning reserve requirement for the pool, input in MW.  The Spinning Reqt column (input in percent) must be blank or 0 to use this column.

This value is used in the pool unit-commitment method to determine the level of spinning reserves required for the pool.  The capability supplied by cycling and committed non-cycling units must be enough to satisfy demand plus the spinning requirement in all hours.

See also Fast Start for Spin column.

NOTE: This value is only used when the Dispatch and Demand setting Use operating reserves is selected.

 NOTE: Specify inputs for any time period (annually, monthly, weekly, hourly, or sub-hourly). For information on specifying a variable's time series, see Entering a Time Series.

 

 Input Tables

 Operating Pools Table

 Spinning Reserve MW Reqt Column


For further assistance, please contact Aurora Support.

Copyright© 1997-2024 Energy Exemplar LLC. All rights reserved.