Battery Unused Load Capacity

Units:MW
Mode:Output Only
Multi-band:False
Default Value:
Validation Rule:
Key Property:No
Description:Unused load capacity (Max Load x Units - Load)

Battery Unused Load Capacity is defined as:

Undispatched Capacity = MAX(0, Max Load × Units - Load)

This is a measure of total load capacity available. To utilise this capacity additional units are allowed to charge and/or transition from discharging to charging.