Facility Outage Factor

Units:%
Mode:Input Only
Multi-band:True
Default Value:100
Validation Rule:Between 0 And 100
Key Property:No
Description:Unit outage rating based on the unit capacity

Facility Outage sets the Outage Operating Level of each unit during the associated Outage or Maintenance outage as a proportion of the Max Operating Level. The default value is zero means that the outage is total. To specify a partial outage use a value greater than zero and less than 100. See the Units Out topic for examples.

Table 1: Outage Factor Example
Property Value Units
Units 1 -
Max Capacity 200 -
Outage Factor 90 %


In this example the outage factor is 90%, and so the implied Outage Operating Level is 10 i.e. (1 - Outage Factor) x Max Operating Level.

Note that Outage Factor overrides Outage Operating Level if both are defined.