Units: | - |
Mode: | Input Only |
Multi-band: | False |
Default Value: | 0 |
Validation Rule: | Any Value |
Key Property: | No |
Description: | Ratio of heat production to electric production |
Generator Power to Heat Ratio is the ratio of heat production relative to the electricity production coming from a CHP plant.
This is the key property that is used to identify the Generator object as a combined heat and power plant.
Example
Property | Value | Units |
---|---|---|
Units | 1 | - |
Max Capacity | 200 | MW |
Min Stable Level | 50 | MW |
Fuel Price | 5 | $/GJ |
Heat Rate | 13 | GJ/MWh |
Min Up Time | 3 | hrs |
Power to Heat Ratio | 0.5 | - |
CHP Electric Heat Rate Incr | 15 | GJ/MWh |
Boiler Heat Rate Incr | 1.2 | GJ/GJ |
Max Boiler Heat | 15 | GJ |