Generator Constraints Operating Hours Coefficient

Units:h
Mode:Input Only
Multi-band:False
Default Value:0
Validation Rule:Any Value
Key Property:No
Description:Coefficient of number of hours of operation.

Generator Constraints Hours of Operation Coefficient is the coefficient of the number of hours of operation of the facility in the given period in the constraint.

This coefficient can be used to create a constraint that limits the number of hours of operation of a multi-unit facility.

Table 1: Hours of Operating Coefficient Example
Membership Property Value
Constraint Sense <=
Constraint RHS
Constraint RHS Day 17.5
Generator Constraints Hours of Operation Coefficient 1


For the example in Table 1 the facility is restricted to operating 17.5 hours per day. Note that adding this coefficient causes the mathematical programming problem to include binary decision variables. And also note that the constraint may not be honoured in a linear relaxation (Unit Commitment) when a partial unit is generating in one operating hour.

This constraint also may generate unexpected results in the partial chronology, since integer and temporal constraints are relaxed.

See also: