Transformer Index

Transformer Input Properties

NameUnitsMulti-bandDefault ValueValidation RuleKey PropertyDescription
AC Fixed Shift Angle°False0FalseThe fixed phase shift angle between the two windings of a single-phase transformer
AC Line Charging SusceptancepuFalse0FalseThe line-charging susceptance of a transformer
AC Tap Ratio-False1>0FalseThe turns ratio of the primary winding of a transformer
Contingency Limit Penalty$/MWhFalse-1FalsePenalty for exceeding contingency flow limits
Enforce Limits-False1In (0,1,2,3)FalseIf flow limits are enforced regardless of Transmission [Constraint Voltage Threshold].
Fixed LossMWFalse0FalseFixed loss on transformer
Forced Outage Rate%True0Between 0 And 100FalseExpected proportion of time the facility is unavailable due to forced outage
Formulate UpfrontYes/NoFalse0In (0,-1)FalseIf constraints should all be formulated upfront rather than checked iteratively.
Limit Penalty$/MWhFalse-1FalsePenalty for exceeding the flow limits on the Transformer.
Loss Allocation-False0.5Between 0 And 1FalseProportion of transformer losses allocated to the receiving node
Maintenance Frequency-True0≥0FalseFrequency of maintenance outages in an annual timeframe
Maintenance Rate%True0Between 0 And 100FalseExpected proportion of time the facility is unavailable due to maintenance
Max Time To RepairhTrue0≥0FalseMaximum time to repair (hr)
Mean Time to RepairhTrue24≥0FalseMean time to repair (hr)
Min Time To RepairhTrue0≥0FalseMinimum time to repair (hr)
Must ReportYes/NoFalse0In (0,-1)FalseIf the Transformer must be reported regardless of Transmission [Report Voltage Threshold].
Outage Max RatingMWTrue0FalseTransformer rating in the reference direction during outage
Outage Min RatingMWTrue0FalseTransformer rating in the counter-reference direction during outage
Overload RatingMWFalse0≥0FalseEmergency rating in the reference direction
Random Number Seed-False0Between 0 And 2147483647FalseRandom number seed assigned to the Line for the generation of outages
RatingMWFalse0≥0FalseMaximum MW rating
ReactancepuFalse0FalseTogether with any resistance this makes up the lines impedance
Repair Time Distribution-True-1In (-1,0,1,2,3,4,5,6,7)FalseDistribution used to generate repair times (Auto,Constant,Uniform,Triangular,Exponential,Weibull,Lognormal,SEV,LEV)
Repair Time Scale-True0FalseRepair time function scale parameter (for exponential,Weibull,lognormal,SEV,LEV)
Repair Time Shape-True0FalseRepair time function shape parameter (for Weibull,lognormal)
ResistancepuFalse0FalseA measure of the transformer's opposition to the flow of electric charge
Screening Mode-False1In (0,1,2)FalseThe set of transformers that should be screened for post-contingency flow under screen contingencies
SusceptancepuFalse0FalseThe reciprocal of the reactance of a circuit and thus the imaginary part of its admittance
Units-False1In (0,1)TrueFlag if transformer is in service
Units Out-False0In (0,1)FalseNumber of [Units] out of service
x-True0FalseValue to pass-through to solution
y-True0FalseValue to pass-through to solution
z-True0FalseValue to pass-through to solution

Transformer Constraints Input Properties

NameUnitsMulti-bandDefault ValueValidation RuleKey PropertyDescription
Flow CoefficientMWFalse0FalseCoefficient of transformer flow equation

Transformer Objectives Input Properties

NameUnitsMulti-bandDefault ValueValidation RuleKey PropertyDescription
Flow CoefficientMWFalse0FalseCoefficient of transformer flow equation

Transformer Output Properties

NameSummary NameProperty GroupPhasesMulti-bandDescription
Available Transfer Capability - MWAvailable Transfer Capability - GWhCapacityLT Plan, MT Schedule, ST ScheduleFalseAvailable transfer capability on the transformer.
Available Transfer Capability Back - MWAvailable Transfer Capability Back - GWhCapacityLT Plan, MT Schedule, ST ScheduleFalseAvailable transfer capability on the transformer in the counter-reference direction.
Discrete Maintenance - MWDiscrete Maintenance - GWhReliabilityPASAFalsePlanned reference direction capacity out of service
Discrete Maintenance Back - MWDiscrete Maintenance Back - GWhReliabilityPASAFalsePlanned counter-reference direction capacity out of service
Distributed Maintenance - MWDistributed Maintenance - GWhReliabilityPASAFalseIdeal reference direction capacity out on maintenance
Distributed Maintenance Back - MWDistributed Maintenance Back - GWhReliabilityPASAFalseIdeal counter-reference direction capacity out on maintenance
Export Cost - $Export Cost - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseCost of energy exported
Export Limit - MWExport Limit - MWProductionLT Plan, MT Schedule, ST ScheduleFalseMaximum flow allowed on the transformer
Export Revenue - $Export Revenue - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseRevenue from energy exported
Flow - MWFlow - GWhProductionLT Plan, MT Schedule, ST ScheduleFalseFlow through the transformer (sent out)
Flow Back - MWFlow Back - GWhProductionLT Plan, MT Schedule, ST ScheduleFalseFlow through the transformer in the counter-reference direction
Forced Outage - MWForced Outage - GWhReliabilityLT Plan, MT Schedule, ST ScheduleFalseCapacity forced out
Forced Outage Rate - %Forced Outage Rate - %ReliabilityLT Plan, MT Schedule, ST ScheduleFalseProportion of installed capacity on forced outage
Hours Congested - hHours Congested - hProductionLT Plan, MT Schedule, ST ScheduleFalseNumber of hours the Transformer is flowing at its [Rating].
Import Cost - $Import Cost - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseCost of energy imported
Import Limit - MWImport Limit - MWProductionLT Plan, MT Schedule, ST ScheduleFalseMinimum flow allowed on the line
Import Revenue - $Import Revenue - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseRevenue from energy imported
Loading - %Loading - %ProductionLT Plan, MT Schedule, ST ScheduleFalseLoading relative to thermal limit.
Loading Back - %Loading Back - %ProductionLT Plan, MT Schedule, ST ScheduleFalseLoading in the counter-reference direction relative to thermal limit.
Loss - MWLoss - GWhProductionLT Plan, MT Schedule, ST ScheduleFalseLosses (sent out)
Loss Back - MWLoss Back - GWhProductionLT Plan, MT Schedule, ST ScheduleFalseLosses on flows in the counter-reference direction
Maintenance - MWMaintenance - GWhReliabilityLT Plan, PASA, MT Schedule, ST ScheduleFalseTotal capacity out of service in the reference direction (discrete + distributed)
Maintenance Back - MWMaintenance Back - GWhReliabilityLT Plan, PASA, MT Schedule, ST ScheduleFalseTotal capacity out of service in the reverse reference direction (discrete + distributed)
Maintenance Rate - %Maintenance Rate - %ReliabilityLT Plan, MT Schedule, ST ScheduleFalseProportion of installed capacity on maintenance outage
Max Flow - MWMax Flow - MWProductionLT Plan, MT Schedule, ST ScheduleFalseMaximum flow
Min Flow - MWMin Flow - MWProductionLT Plan, MT Schedule, ST ScheduleFalseMinimum flow
Overload Export Limit - MWOverload Export Limit - MWProductionLT Plan, MT Schedule, ST ScheduleFalseMaximum post-contingency flow allowed on the transformer
Overload Import Limit - MWOverload Import Limit - MWProductionLT Plan, MT Schedule, ST ScheduleFalseMinimum post-contingency flow allowed on the line
Rental - $Rental - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseTransmission rent
Rental Back - $Rental Back - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseRental / settlement surplus in the counter-reference direction
Service Factor - %Service Factor - %ReliabilityLT Plan, MT Schedule, ST ScheduleFalseProportion of installed capacity available for transfer
Shadow Price - $/MWShadow Price - $/MWProductionLT Plan, MT Schedule, ST ScheduleFalseShadow/expansion price
Violation - MWViolation - GWhProductionLT Plan, MT Schedule, ST ScheduleFalseViolation of flow limit
Violation Back - MWViolation Back - GWhProductionLT Plan, MT Schedule, ST ScheduleFalseViolation of the flow limit in the counter-reference direction.
Violation Back Hours - hViolation Back Hours - hProductionLT Plan, MT Schedule, ST ScheduleFalseNumber of hours the flow limit is violated in the counter-reference direction.
Violation Cost - $Violation Cost - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseCost of violating flow limits
Violation Cost Back - $Violation Cost Back - $000ProductionLT Plan, MT Schedule, ST ScheduleFalseCost of violating the flow limit in the counter-reference direction.
Violation Hours - hViolation Hours - hProductionLT Plan, MT Schedule, ST ScheduleFalseNumber of hours the Transformer Flow exceeds the [Rating].
Voltage - kVVoltage - kVProductionLT Plan, MT Schedule, ST ScheduleFalseVoltage of the transformer
x xPass-throughLT Plan, MT Schedule, ST ScheduleTrueValue to pass-through to solution
y yPass-throughLT Plan, MT Schedule, ST ScheduleTrueValue to pass-through to solution
z zPass-throughLT Plan, MT Schedule, ST ScheduleTrueValue to pass-through to solution