Reserve Batteries Max Charge Response

Units:MW
Mode:Input Only
Multi-band:False
Default Value:1E+30
Validation Rule:≥0
Key Property:No
Description:Maximum reserve response from charging load adjustment

Reserve Batteries Max Charge Response is the maximum reserve response that can be effected through variations to a battery's Load level.

Reserve response from adjustments to a battery's Generation level can be limited by Max Response.

Total reserve provision from the whole battery (geneation + load) can be limited by Total Response.

Reserve Batteries Max Charge Response sets a limit on the response that can be made by a unit at a battery in providing this reserve service. Batteries providing 'raise' response by decreasing Available Response and 'lower' response by increasing Available Response. The feasible range of pump load response is up to Max Response.