Facility Max Ramp Up

Units:-
Mode:Input Only
Multi-band:False
Default Value:1E+30
Validation Rule:≥0
Key Property:No
Description:Maximum ramp up rate

Facility Max Ramp Up sets a limit on the amount that Production can increase in any given interval. The value is the maximum change in production per hour. This limit applies for Production ranges between the minimum operating level and Max Operating Level.

For multi-unit facilities the available ramp up is defined as:

By default the ramping limit is a hard constraint meaning that no violation is allowed. To create soft constraints with a penalty price use the Max Ramp Up Penalty property.

Table 1: Max Ramp Up Example
Property Value Units
Units 1 -
Max Operating Level 100 -
Min Operating Factor 40 %
Max Ramp Up 30 -
Max Ramp Up Penalty 100 $
Max Ramp Down 30 -
Max Ramp Down Penalty 100 $


Related reporting properties:

See also: