Flow Control Max Impedance

Units:pu
Mode:Input Only
Multi-band:False
Default Value:0
Validation Rule:Any Value
Key Property:No
Description:Max Impedance

Flow Control Max Impedance is user specified Impedance limits for DSR, TCSC and MSSR type of devices. The Impedance limitation can be derived as a function of line flow:

FlowFC ≥ - FlowLine x Xmax / (XLine) if FlowLine is positive ( FlowLine > 0) FlowFC ≤ - FlowLine x Xmax / (XLine) if FlowLine is negative ( FlowLine < 0)

Therefore, the Max Impedance input is applied as flow/angle limits and replacing the user input Min Angle. Note that Max Impedance must be larger than or equal to Min Impedance.