Offline Ancillary Up Time Column
Column Type = Text

The Offline Ancillary Up Time column represents how long (in minutes) it will take for an offline unit to be online enough to provide ancillary services. It basically acts like a Boolean for each product, determining whether or not the resource can contribute to the product while offline.

For example, if a resource has a Offline Ancillary Up Time value of 30 minutes in the Resources table and participated in all four of the products shown below, then when it was offline it would only be able to contribute to the NonSpin product (since for Spin, RegDown, and RegUp the Time Length < 30).

 NOTE: This field is only used for Commitment resources. A resource which is cycling is assuming to be able to ramp up quickly.

 NOTE: If the FUEL reference is specified for this variable the value in the Fuel Table will be applied.

 

 Input Tables

 New Resources Table

 Offline Ancillary Up Time Column


For further assistance, please contact Aurora Support.