The Storage Control Type column specifies the criteria to be used in scheduling the generation available for a given storage unit. The options are:
Price (or NULL) - The default control method is to use the price series in the pre-forecast and schedule discretionary generation energy in the highest set of hours in that week ahead forecast.
Demand - Will target generation for the highest demand hours of the week in the zone.
DemandNetMR - Will shape to zone demand net of the zone's must-run energy from non-commitment units.
PoolDemand - Will target generation for the highest demand hours of the week in the pool.
PoolDemandNetMR - Will shape to pool demand net of the pool's must-run energy from non-commitment units.
NOTE: If the FUEL reference is specified for this variable the value in the Fuel Table will be applied.
For more information, see Storage Resources.
Storage Control Type Column
For further assistance, please contact Aurora Support.