Minimum Generation Column

This optional column is used to specify the minimum level of the generation required from each resource.  Accepted input are a value between 0 and 1, with the default value being 0.  When a non-zero value is entered, a MW minimum generation level is calculated as [Capacity]*[Generating Availability]*[Minimum Generation].  The optimization only allows the unit to generate (discharge) at or above this level when in operation, though it can have a 0 MW generation level.  The available charging levels are not directly affected by this parameter.  

NOTE: Including this parameter on many storage units can increase the problem size significantly.  

 NOTE: Inputs can be specified for any time period (annual, monthly, weekly, hourly or sub-hourly). For information on how to specify a time series for a variable, see Entering a Time Series.

 

 Input Tables

 Storage Table

 Minimum Generation Column


For further assistance, please contact Aurora Support.