Units: | MW |
Mode: | Output Only |
Multi-band: | False |
Default Value: | |
Validation Rule: | |
Key Property: | No |
Description: | Pump capacity online but undispatched |
Generator Undispatched Pump Capacity is defined as:
Undispatched Capacity = MAX(0, Input Pump Load × Units Pumping - Output Station-wide Pump Load)
This is a measure of how much pumping (load) capacity is available but not utilized given the unit commitment solution.
See also: