Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Build Cost | $ | True | 0 | False | Cost of building the Flow Path | |
Bundle Size | - | False | 0 | ≥0 | False | Size of bundles flowed on the Flow Path |
Economic Life | yr | False | 30 | ≥0 | False | Economic life of the Flow Path (period over which fixed costs are recovered). |
Efficiency | % | False | 100 | False | Proportion of flow received net of any losses | |
Expansion Optimality | - | False | 2 | In (0,2) | False | Expansion planning integerization scheme. |
Flow Charge | $/~ | False | 0 | False | Unit cost of flowing the Commodity over the Flow Path | |
FO&M Charge | $ | False | 0 | False | Annual fixed operation and maintenance charge | |
Forced Outage Rate | % | True | 0 | Between 0 And 100 | False | Expected proportion of time the facility is unavailable due to forced outage |
Initial Flow | ~ | True | 0 | False | Initial flow with optional delay time | |
Initial Flow Delay | h | True | 0 | False | Delay on the Initial Flow in this band | |
Integerization Horizon | yr | False | -1 | ≥-1 | False | Number of years over which the expansion decisions are integerized |
Lead Time | yr | False | 0 | ≥0 | False | Number of years after which the expansion project can begin |
Maintenance Frequency | - | True | 0 | ≥0 | False | Frequency of maintenance outages in an annual time frame |
Maintenance Rate | % | True | 0 | Between 0 And 100 | False | Expected proportion of time the facility is unavailable due to maintenance |
Max Flow | ~ | False | 1E+30 | False | Maximum flow on the Flow Path in any interval | |
Max Flow Day | ~ | False | 1E+30 | False | Maximum flow on the Flow Path in any day | |
Max Flow Hour | ~ | False | 1E+30 | False | Maximum flow on the Flow Path in any hour | |
Max Flow Month | ~ | False | 1E+30 | False | Maximum flow on the Flow Path in any month | |
Max Flow Week | ~ | False | 1E+30 | False | Maximum flow on the Flow Path in any week | |
Max Flow Year | ~ | False | 1E+30 | False | Maximum flow on the Flow Path in any year | |
Max Time To Repair | h | True | 0 | ≥0 | False | Maximum time to repair |
Max Units Built | - | False | 0 | ≥0 | False | Maximum number of units automatically constructed in aggregate over the planning horizon |
Max Units Built in Year | - | False | 1E+30 | ≥0 | False | Maximum number of units automatically constructed in any single year of the planning horizon |
Max Units Retired | - | False | 0 | ≥0 | False | Maximum number of units automatically retired in aggregate over the planning horizon |
Max Units Retired in Year | - | False | 1E+30 | ≥0 | False | Maximum number of units automatically retired in any single year of the planning horizon |
Mean Time to Repair | h | True | 24 | ≥0 | False | Mean time to repair |
Min Flow | ~ | False | -1E+30 | False | Minimum flow on the Flow Path in any interval | |
Min Flow Day | ~ | False | -1E+30 | False | Minimum flow on the Flow Path in any day | |
Min Flow Hour | ~ | False | -1E+30 | False | Minimum flow on the Flow Path in any hour | |
Min Flow Month | ~ | False | -1E+30 | False | Minimum flow on the Flow Path in any month | |
Min Flow Week | ~ | False | -1E+30 | False | Minimum flow on the Flow Path in any week | |
Min Flow Year | ~ | False | -1E+30 | False | Minimum flow on the Flow Path in any year | |
Min Operating Factor | % | False | 0 | Between 0 And 100 | False | Minimum operating level when operating |
Min Time To Repair | h | True | 0 | ≥0 | False | Minimum time to repair |
Min Units Built | - | False | 0 | ≥0 | False | Minimum number of units automatically constructed in aggregate over the planning horizon |
Min Units Built in Year | - | False | 0 | ≥0 | False | Minimum number of units automatically constructed in any single year of the planning horizon |
Min Units Retired | - | False | 0 | ≥0 | False | Minimum number of units automatically retired in aggregate over the planning horizon |
Min Units Retired in Year | - | False | 0 | ≥0 | False | Minimum number of units automatically retired in any single year of the planning horizon |
Outage Max Rating | ~ | True | 0 | False | Flow Path Max Flow during the outage | |
Outage Min Rating | ~ | True | 0 | False | Flow Path Min Flow during the outage | |
Project Start Date | - | False | 36526 | ≥0 | False | Start date of Flow Path project, for expansion planning. |
Random Number Seed | - | False | 0 | Between 0 And 2147483647 | False | Random number seed assigned to the flow path for the generation of outages |
Repair Time Distribution | - | True | -1 | In (-1,0,1,2,3,4,5,6,7) | False | Distribution used to generate repair times (Auto,Constant,Uniform,Triangular,Exponential,Weibull,Lognormal,SEV,LEV) |
Repair Time Scale | - | True | 0 | False | Repair time function scale parameter (for exponential,Weibull,lognormal,SEV,LEV) | |
Repair Time Shape | - | True | 0 | False | Repair time function shape parameter (for Weibull,lognormal) | |
Retirement Cost | $ | False | 0 | False | Cost of retiring the Flow Path | |
Technical Life | yr | False | 1E+30 | ≥0 | False | Technical lifetime of the Flow Path |
Traversal Time | h | False | 0 | ≥0 | False | Time taken for flows to traverse the Flow Path |
Units | - | False | 1 | In (0,1) | True | Flag if the Flow Path is in service |
Units Out | - | True | 0 | ≥0 | False | Number of units out of service due to maintenance |
WACC | % | False | 10 | ≥0 | False | Weighted average cost of capital |
x | - | True | 0 | False | Value to pass-through to solution | |
y | - | True | 0 | False | Value to pass-through to solution | |
z | - | True | 0 | False | Value to pass-through to solution |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Flow Back Coefficient | - | False | 0 | False | Coefficient of Flow Path flow at the sending node | |
Flow Coefficient | - | False | 0 | False | Coefficient of Flow Path flow | |
Flow Forward Coefficient | - | False | 0 | False | Coefficient of Flow Path flow at the receiving node | |
Units Built Coefficient | - | False | 0 | False | Coefficient of number of units built | |
Units Built in Year Coefficient | - | False | 0 | False | Coefficient of number of units built in the year | |
Units Retired Coefficient | - | False | 0 | False | Coefficient of number of units retired | |
Units Retired in Year Coefficient | - | False | 0 | False | Coefficient of number of units retired in the year |
Name | Units | Multi-band | Default Value | Validation Rule | Key Property | Description |
---|---|---|---|---|---|---|
Flow Back Coefficient | - | False | 0 | False | Coefficient of Flow Path flow at the sending node | |
Flow Coefficient | - | False | 0 | False | Coefficient of Flow Path flow | |
Flow Forward Coefficient | - | False | 0 | False | Coefficient of Flow Path flow at the receiving node | |
Units Built Coefficient | - | False | 0 | False | Coefficient of number of units built | |
Units Built in Year Coefficient | - | False | 0 | False | Coefficient of number of units built in the year | |
Units Retired Coefficient | - | False | 0 | False | Coefficient of number of units retired | |
Units Retired in Year Coefficient | - | False | 0 | False | Coefficient of number of units retired in the year |
Name | Summary Name | Property Group | Phases | Multi-band | Description |
---|---|---|---|---|---|
Available Capacity - ~ | Available Capacity - ~ | Capacity | LT Plan, MT Schedule, ST Schedule | False | Available capacity |
Build Cost - $000 | Build Cost - $000 | Expansion | LT Plan | False | Cost of building the Flow Path |
Capacity Built - ~ | Capacity Built - ~ | Expansion | LT Plan | False | Capacity built |
Capacity Retired - ~ | Capacity Retired - ~ | Expansion | LT Plan | False | Capacity retired |
Discrete Maintenance - ~ | Discrete Maintenance - ~ | Reliability | PASA | False | Planned reference direction capacity out of service |
Discrete Maintenance Back - ~ | Discrete Maintenance Back - ~ | Reliability | PASA | False | Planned counter-reference direction capacity out of service |
Distributed Maintenance - ~ | Distributed Maintenance - ~ | Reliability | PASA | False | Ideal reference direction capacity out on maintenance |
Distributed Maintenance Back - ~ | Distributed Maintenance Back - ~ | Reliability | PASA | False | Ideal counter-reference direction capacity out on maintenance |
Export Limit - ~ | Export Limit - ~ | Production | LT Plan, MT Schedule, ST Schedule | False | Maximum flow allowed on the Flow Path |
Flow - ~ | Flow - ~ | Production | LT Plan, MT Schedule, ST Schedule | False | Net flow of the Commodity |
Flow Back - ~ | Flow Back - ~ | Production | LT Plan, MT Schedule, ST Schedule | False | Commodity flow in the counter-reference direction |
Flow Cost - $ | Flow Cost - $000 | Production | LT Plan, MT Schedule, ST Schedule | False | Cost of flows |
Flow Forward - ~ | Flow Forward - ~ | Production | LT Plan, MT Schedule, ST Schedule | False | Commodity flow in the reference direction |
Flows in Transit - ~ | Flows in Transit - ~ | Production | LT Plan, MT Schedule, ST Schedule | False | Commodity flow in transit at the end of the period |
FO&M Cost - $ | FO&M Cost - $000 | Production | LT Plan, MT Schedule, ST Schedule | False | Fixed operation and maintenance cost |
Forced Outage - ~ | Forced Outage - ~ | Reliability | LT Plan, MT Schedule, ST Schedule | False | Capacity lost to forced outage |
Forced Outage Hours - h | Forced Outage Hours - h | Reliability | LT Plan, MT Schedule, ST Schedule | False | Number of hours on forced outage |
Forced Outage Rate - % | Forced Outage Rate - % | Reliability | LT Plan, MT Schedule, ST Schedule | False | Proportion of capacity on forced outage |
Hours Congested - h | Hours Congested - h | Production | LT Plan, MT Schedule, ST Schedule | False | Number of hours the Flow Path is congested |
Hours Congested Back - h | Hours Congested Back - h | Production | LT Plan, MT Schedule, ST Schedule | False | Number of hours the Flow Path is congested in the counter-reference direction |
Hours Congested Forward - h | Hours Congested Forward - h | Production | LT Plan, MT Schedule, ST Schedule | False | Number of hours the Flow Path is congested in the reference direction |
Import Limit - ~ | Import Limit - ~ | Production | LT Plan, MT Schedule, ST Schedule | False | Minimum flow allowed on the Flow Path |
Installed Capacity - ~ | Installed Capacity - ~ | Capacity | LT Plan, PASA, MT Schedule, ST Schedule | False | Installed capacity (Max Flow x Units) |
Loading - % | Loading - % | Production | LT Plan, MT Schedule, ST Schedule | False | Loading relative to flow limit |
Loading Back - % | Loading Back - % | Production | LT Plan, MT Schedule, ST Schedule | False | Loading in the counter-reference direction relative to flow limit |
Losses - ~ | Losses - ~ | Production | LT Plan, MT Schedule, ST Schedule | False | Losses incurred |
Maintenance - ~ | Maintenance - ~ | Reliability | LT Plan, PASA, MT Schedule, ST Schedule | False | Capacity out on maintenance |
Maintenance Back - ~ | Maintenance Back - ~ | Reliability | LT Plan, PASA, MT Schedule, ST Schedule | False | Total capacity out of service in the reverse reference direction (discrete + distributed) |
Maintenance Hours - h | Maintenance Hours - h | Reliability | LT Plan, MT Schedule, ST Schedule | False | Number of hours on maintenance |
Maintenance Rate - % | Maintenance Rate - % | Reliability | LT Plan, MT Schedule, ST Schedule | False | Proportion of capacity on maintenance outage |
Retirement Cost - $000 | Retirement Cost - $000 | Expansion | LT Plan | False | Cost of retiring the Flow Path |
Service Factor - % | Service Factor - % | Reliability | LT Plan, MT Schedule, ST Schedule | False | Proportion of capacity available for production |
Shadow Price - $/~ | Shadow Price - $/~ | Production | LT Plan, MT Schedule, ST Schedule | False | Shadow price |
Shadow Price Back - $/~ | Shadow Price Back - $/~ | Production | LT Plan, MT Schedule, ST Schedule | False | Shadow price of interface limit in the counter-reference direction |
Shadow Price Forward - $/~ | Shadow Price Forward - $/~ | Production | LT Plan, MT Schedule, ST Schedule | False | Shadow price in the reference direction |
Units | Units | Production | LT Plan | False | Flag if the Flow Path is in service |
Units Built | Units Built | Expansion | LT Plan | False | Flag if the Flow Node is built in this year |
Units Out | Reliability | LT Plan, MT Schedule, ST Schedule | False | Number of units out of service | |
Units Retired | Units Retired | Expansion | LT Plan | False | Flag if the Flow Node is retired in this year |
x | x | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |
y | y | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |
z | z | Pass-through | LT Plan, MT Schedule, ST Schedule | True | Value to pass-through to solution |