Emissions Logic

Emissions logic can be summarized as follows:

Where:
Output = Hourly output in MWh
HR = Unit average heat rate for the hour in Btu/kWh
R = Unit emission rate in lb/mmBtu
L = Emission limit applicable to the unit in lb/mmBtu
P = Emission price applicable to the unit in $/Ton
B = Intensity baseline in Ton/MWh

Treatment of emissions is controlled using the input tables: Emission Price and Emission Rate.  Emission cost can be included in dispatch or value by using the Include Emissions Costs in Dispatch and Include Emissions in Value Reporting switches in the Resource folder of Simulation Options - Reporting Parameters.

 NOTE: Emission data will always be displayed; these options only determine if the costs will be applied in the model.

See Emissions Overview for more information on using resource emissions.