Forced Outage Column
Column Type = Text

The Forced Outage column is used to specify the percentage of time the resource will be unavailable due to unscheduled outages.

The Forced Outage field reduces the plant capacity by multiplying the plant capacity by the quantity 1 minus the forced outage rate divided by 100. The forced outage rate for each dispatch hour will derate the unit capacity.

Example:  For a plant with a capacity of 120 MW and a Forced Outage rate of 10%:

120*(1-10/100) = 108 MW derated capacity. This capacity would be applied to the unit every hour.

Use the Frequency Duration or Convergent Outage Method option (located in the Resource folder of Simulation Options) to remove a unit from service for a random unscheduled outage.

 NOTE: Specify inputs for any time period (annually, monthly, weekly, hourly, or sub-hourly). For information on specifying a variable's time series, see Entering a Time Series.

 