Capacity_Obligation Column
Units = MW

For zones that have the Capacity Obligation Peak Months column populated, the value for each year will be equal to

[Peak Demand] * [1 + (Planning Reserve Requirement) / 100] * [Capacity Obligation Scaling Factor]

Where:

If more scaling factors are entered, then these will also be multiplied to get the final value.