Facility Forced Outage

Units:-
Mode:Input/Output
Multi-band:False
Default Value:0
Validation Rule:≥0
Key Property:No
Description:Capacity lost to forced outage
Input

Facility Forced Outage is the production capacity lost to random outages. It can be used as an input to define a known pattern of outages and can be defined with a Variable object or passed as an input from an Interleaved simulation to coordinate outage between models.

Output

The definition of Forced Outage as an output varies by simulation phase:

LT Plan
Forced Outage reports the derating applied to capacity to account for Forced Outage Rate:

Forced Outage = ∑ ( b ) ( Forced Outage Rateb × (Max Operating Level - Outage Ratingb)

where:
b indexes the bands of Forced Outage Rate

MT Schedule and ST Schedule

Forced Outage reports the capacity on outage from the realized outage events. Thus for any given event:

Forced Outage =∑ ( b ) (Max Operating Level - Outage Ratingb) × Units Outb

Note that if MT Schedule Chronology = "Partial" then multiple discrete events may combine together in any given period as a function of the slicing of the duration curves and thus this profile may then resemble a sculpted derating rather than discrete events.