Generator Unit Commitment Optimality

Units:-
Mode:Input Only
Multi-band:False
Default Value:-1
Validation Rule:In (-1,0,1,2,3)
Key Property:No
Description:Unit commitment integerization scheme for the generator.

This setting overrides the global option (Production Unit Commitment Optimality) and provides additional functionality:

Automatic (value = -1)
Unit commitment optimality is set by the global option.
Linear Relaxation (value = 0), Rounded Relaxation (value = 1), Integer Optimal (value = 2)
please refer to Production Unit Commitment Optimality for details
Dynamic Program (value = 3)
Unit commitment (for this Generator) is optimized in a dynamic program executed between MT Schedule and ST Schedule. Thus MT Schedule must be enabled for this option to apply. The dynamic program is described in the Unit Commitment.

See also: