Generator Constraints Firm Capacity Coefficient

Units:MW
Mode:Input Only
Multi-band:False
Default Value:0
Validation Rule:Any Value
Key Property:No
Description:Coefficient of capacity as measured by [Firm Capacity]

Generator Constraints Firm Capacity Coefficient is the left-hand side coefficient of Firm Capacity in the constraint.

With the coefficient represented by a(i,j) the following term is added to the formulation:

... + a(i,j) × Generator Firm Capacity ... {≤, ≥, =} bj


Note that this constraint accounts for the effect of Maintenance events on Firm Capacity according to Maintenance Generators Outage Firm Capacity.