Generator Constraints Units Pumping Coefficient

Units:-
Mode:Input Only
Multi-band:False
Default Value:0
Validation Rule:Any Value
Key Property:No
Description:Coefficient on the number of units pumping

Generator Constraints Units Pumping Coefficient is the left-hand side coefficient on the number of Generator Units Pumping in the constraint.

With the coefficient represented by a(i,j) the following term is added to the formulation:

... + a(i,j) × Generator Units Pumping ... {≤, ≥, =} bj