Use the optional CONE Column to select a resource representing a cap to capacity uplift payments via a defined Cost Of New Entrant (CONE) unit.
This column is applied when the Use CONE method is selected in the Long-Term folder of Simulation Options. If no CONE unit is selected when using this method, the unit with the highest Fixed O&M cost will set the limit on the capacity prices.
Additionally, if more than one CONE unit is selected within a zone/pool, Aurora uses the cheapest unit out of the identified set. In practice, a CT is typically selected to set the CONE, but any resource can be selected.
NOTE: This column is NOT time series compatible. To adjust CONE participation throughout time, add additional records with unique First Eligible Year/Resource Begin Date and Last Eligible Year/Resource End Date fields.
NOTE: If you specify this variable's FUEL reference, the value in the Fuel Table will be applied.