Capacity Diagnostic Output Level

This setting controls the amount of output written to the LTCapacityLog and LTMargResLog output tables when performing a long-term run using the target reserve margin. Available levels include:

 NOTE: Level 2 can produce very large amounts of output. Each iteration will produce approximately 16 records for each year of the study within each zone. A 25 year study for 20 zones and 50 iterations will produce roughly 400,000 records (16 records * 25 years * 20 zones * 50 iterations). The number of columns in each record will correspond to length of the study in years plus 8 columns (33 columns for a 25 year study). When using level 2 output, make sure you have the Maximum Output Records set to a low value so you will not run out of system memory during a long-term run.

See the Knowledge Base article Long-Term Studies Using Reserve Margins for more information.

 Simulation Options

 Long Term

 Capacity Diagnostic Output Level

 


For further assistance, please contact Aurora Support.