"_Input_" Tables

Tables with the "_Input_" prefix are input tables added to the output database. Now, the "_Input_" tables in the output database will be named as follows:

There are three methods for using Write Input to Output:

With Write selected input data to output option turned on, the selected input tables will be added automatically to the output database with the prefix "{Table_Type_ShortKey} + "_Input_" + {Input_Table_Name}" at the completion of a run. Table_Type_ShortKey is a key based on Table Type of Input Table retrieved from following table:

 

Table Type ShortKey   Table Type ShortKey   Table Type ShortKey
Ancillary Services Ancillary   Hydro Monthly HydMn   Time Series Pattern TSP
Areas Areas   Hydro Vectors HydVect   Time Series SubHourly TSSH
Capacity Price  CapPrice   Link Link   Time Series Weekly TSW
Constraint Constraint   Maintenance Schedule Maint   Timeslice Definition TimeDef
Custom Constraint CustCon   New Resources NewRes   Unit Conversion UnitConv
Custom Constraint Matrix CustConMat   Operating Pools OpPools   Unknown Unknown
Custom Decision Variable CustDecVar   Operating Rules OpRule   Zone Definition ZoneDef
Daily Change DayChange   ORM ORM   Aggregate Area AggArea
Demand Demand   Portfolio Contract PortCon   AURORA Zone Map AurZonMap
Demand Collection DemColl   Portfolio Information PortInfo   BranchOutage BranOut
Demand Escalation DemEsc   Portfolio Optimization PortOpt   Bus Load Defintion BusLoadDef
Demand Hourly DemHr   Portfolio Resource PortRes   Contingency Contingency
Demand Monthly DemMn   Resource Dependency ResDepend   Corridor Def CorrDef
Demand Monthly Peak DemMnPk   Resource Groups ResGroup   Corridor Limit CorrLim
Dispatch Uncertainty DispUnc   Resource Modifier RMT   DC Lines DCLines
Electricity Price ElecPrice   Resources Resources   Filter Sets FilSets
Emission Price EmPrice   Risk Risk   FTR Reporting FTRRep
Emission Rate EmRate   Storage Storage   Gen Map GenMap
Energy Conversion EnConvers   Segment Definition SegDef   Hub Definition HubDef
Energy Converters EnConvert   Supplemental Parameters SuppParam   Individ Hours IndHrs
Fuel Fuel   Supply Curve SupplyCurve   LF Area Map LFAreaMap
General Info GenInfo   System Diagram SysDiag   Supplemental Area SuppArea
Heat Rate Definitions HRDef   Time Series Annual TSA   Supplemental Branch SuppBran
Hubs Hubs   Time Series Generic TSG   Supplemental Gen SuppGen
Hydro Composite Reservoir HydCompRes   Time Series Hourly TSH   Transmission Diagnostic TransDiag
      Time Series Monthly TSM      

 

NOTE: For table types not in above table, we create a custom ShortKey by joining first three letters of each word in the table, e.g., "Table Type" creates ShortKey, "TabTyp".

 

NOTE: The input data written to output will include the same changes used in the simulation which produced the Output tables. If the Output was created using an Active Change Set, the input tables written to output will reflect the changes in that Change Set. If the Study Case List is used, the input tables will reflect all Change Sets selected for use in the study. If multiple cases are run from the Study Case List, the input tables will reflect the Change Sets used in the first study only, since the input tables are only written once before all study cases finish. If no Change Sets are active, then only the base data will be written.

NOTE: Input tables can be written to any output database type. However, Output Queries are only compatible with xmpSQL, SQLServer and MySQL output formats.

 NOTE: Column names that begin with numeric characters are proceeded by an underscore in the output database.

 Output Tables

 "_Input_" Tables


For further assistance, please contact Aurora Support.